Frontiers in Biomedical Technologies. 2014; 1 (2): 91-101
in English | IMEMR | ID: emr-191525

ABSTRACT

Purpose: Clinical myocardial perfusion SPECT is commonly performed using static imaging. Dynamic SPECT enables extraction of quantitative as well as relative perfusion information. We aimed to evaluate the ability of dynamic SPECT for regular perfusion assessment in comparison to conventional SPECT in the context of thallium-201. Methods: Simulations were performed utilizing a 4D-NCAT phantom for a dual-head gamma camera via the SIMIND Monte-Carlo simulator. 64s acquisition time-frames were used to track these dynamic changes. Different summations of time-frames were performed to create each dataset, which were compared to a standard static dataset. In addition, the effect of different delay-times post-injection was assessed. Twenty-segment analysis of perfusion was performed via the QPS analyser. Dynamic data were subsequently acquired in clinical studiesusing simulation-optimized protocols. Results: For different summations of time-frames, perfusion scores in the basal and mid regions revealed 14.4% and 7.3% increases in dynamic SPECT compared to conventional imaging, with maximum changes in the basal anterior, while the distal and apical segments did not show noticeable changes. Specifically, dynamic imaging including 4 to 6 time-frames yielded enhanced correlation [R=0.957] with conventional imaging, in comparision to the usage of less time frames. Greatest correlation with conventional imaging was obtained for post-injection delays of 320 to 448s [R=0.982 to R=0.988]. Conclusion: While dynamic SPECT opens up an important opportunity for quantitative assessment [e.g. via generation of kinetic parameters], it was shown to generate highly consistent perfusion information compared to established conventional imaging. Future work focuses on merging these two important capabilities

2.
IHJ-Iranian Heart Journal. 2012; 12 (4): 30-36
in English | IMEMR | ID: emr-178326

ABSTRACT

Nowadays, myocardial perfusion imaging [MPI] plays an important role in the early diagnosis of patients with coronary artery disease [CAD]. This study sought to assess the performance of MPI alongside chest paint and ST-segment changes during the stress test by comparison with angiography in the diagnosis of coronary artery stenosis. To that end, the accuracy of these modalities in terms of sensitivity and specificity and the degree of greement between their results in the diagnosis of coronary artery stenosis were evaluated. The study population, selected from those with known or suspected CAD, was comprised of 85 patients [67 males] at a mean age of 53.7 +/- 9.6 years. All the patients were subjected to SPECT imaging of the blood supply to the heart muscle during a two-day state of stress [either pharmacologically with Dipyridamole or through exercise test] and during rest via the injection of 99m Tc - MIBI. ST-segment changes during stress as well as clinical symptoms were recorded. All the patients underwent coronary angiography within two weeks, and coronary artery stenosis >50% was considered positive. Finally, the results of chest pain, ECG changes, and MPI for the evaluation of coronary artery involvement were compared with those of angiography as the gold standard. Of the 85 patients, who underwent angiography, 10 patients had normal coronary angiography, 22 single-vessel disease, 28 two-vessel disease, and 25 three-vessel disease. ST- segment depression and ST-segment elevation were observed in 40 and 6 patients, respectively. The ECG had sensitivity of 57% and specificity of 70% in the diagnosis of coronary artery stenosis. Fifteen patients had chest pain during stress; all of them had coronary involvement according to angiography. Of the 70 patients with no chest pain, coronary angiography was positive in 62 cases; accordingly, chest pain had sensitivity of 20% and specificity of 100% in the diagnosis of coronary artery stenosis. There were 80 patients with abnormal MPI, including 387 fixed and reversible defects. Therefore, MPI had sensitivity of 79%, specificity of 70%, and diagnostic accuracy of 76% in the diagnosis of coronary artery stenosis. MPI enjoyed higher diagnostic accuracy and agreement coefficient than did chest pain and ST-segment changes in the diagnosis of coronary artery stenosis. Given the acceptable results of MPI in the diagnosis of coronary artery stenosis, this modality could be valuable in the management of CAD patients


Subject(s)
Humans , Female , Male , Electrocardiography , Coronary Angiography , Chest Pain , Myocardial Perfusion Imaging , Tomography, Emission-Computed, Single-Photon
3.
Iranian Journal of Nuclear Medicine. 2007; 15 (27): 8-13
in English | IMEMR | ID: emr-94252

ABSTRACT

In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation [MPLE] for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filtration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poisson noise and inherent smoothness of this kind of images. We applied this approach on both simulated and real SPECT images. Monte Carlo simulations were generated with the SIMSET package to model the physical processes and instrumentation used in emission imaging. Cardiac, brain and NEMA phantom SPECT images were obtained using a single-head, Argus model SPECT system. The performance of this method has been evaluated both qualitatively and quantitatively with power spectrum, SNR and noise level measurements on simulated and real SPECT images. For NEMA phantom images, the measured noise levels before [M[b]] and after [M[a]] denoising with Platelet-based MPLE approach were M[b]=2.1732, M[a]=0.1399. In patient study for 32 cardiac SPECT images, the difference between noise level and SNR before and after the approach were [M[b]=3.7607, SNR[b]=9.7762, M[a]=0.7374, SNR[a]41.0848] respectively. Thus the Coefficient of variance [C.V] of SNR values for denoised images with this algorithm as compared with Butterworth filter, [145/33%] was found. For 32 brain SPECT images the Coefficient Variance of SNR values, [196/17%] was obtained. Our results shows that, Platelet-based MPLE is a useful method for denoising SPECT images considering better homogenous image, improvements in SNR, better radioactive uptake in target organ and reduction of interfering activity from background radiation in comparison to that of other conventional denoising methods


Subject(s)
Humans , Phantoms, Imaging , Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography , Tomography, Emission-Computed, Single-Photon
4.
Iranian Journal of Nuclear Medicine. 2007; 15 (27): 1-8
in English, Persian | IMEMR | ID: emr-94255

ABSTRACT

Filtering can greatly affect the quality of clinical images. Determining the best filter and the proper degree of smoothing can help to ensure the most accurate diagnosis. Forty five patient's data aquired during brain phantom SPECT studies were reconstructed using filtered back-projection technique. The ramp, Shepp-Logan, Cosine, Hamming, Hanning, Butterworth, Metz and Wiener filters were examined to find the optimum condition for each filter. For each slice image, 6200 reconstruction options were considered. The corresponding planar image of each slice was used as the reference image. The quality of reconstructed images was determined using universal image quality index [UIQI]. Four nuclear medicine physicians evaluated the images to choose the best of the filters. Images with best resolution, contrast, smoothness and overall quality were selected by nuclear medicine physicians depending on filters used to generate the best image. A significant difference [p<0.05] between the filters regarding these parameters were observed. The results of this study revealed that maximum resolution and contrast could be obtained using both Metz and Wiener filters. However, the best quality images were generated by using Butterworth filter


Subject(s)
Humans , Brain , Filtration , Image Enhancement
5.
Iranian Journal of Nuclear Medicine. 2007; 15 (27): 24-35
in English, Persian | IMEMR | ID: emr-94258

ABSTRACT

Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanners in cardiology is evaluated using a dedicated PET simulator. In this study only the design of the system were evaluated. Activity and attenuation phantoms were produced using 4D-NCAT phantom. EC AT EXACT HR+, EC AT 953B, ECAT 966, EC AT ART, GE Advance and 16HI-REZ scanners were simulated using Eidolon PET simulator and the output sinograms were reconstructed using STIR software. The reconstructed images were processed using Interview software installed on the Mediso cardiac imaging system. Counts of pixels determined by ROI were used to drawn curves and then the correlations of these curves calculated using SPSS. True coincidences 2D was 4651791 +/- 5900 for ECAT 966, 4651965 +/- 5660 for ECAT ART, 4742731 +/- 5328 for ECAT EXACT HR+, 6018435 +/- 5167 for ECAT 953B, 6566769 +/- 4734 for GE Advance and 6846339 +/- 51850 for 16HI-REZ. Resulted correlations calculated for these scanners were 0.806, 0.795, 0.718, 0.858, 0.726 and 0.896 respectively. There was a considerable different in scatter fractions of different scanners. Curves drawn using count of pixels determined by ROI and correlations of these curves showed differences in performances of scanners in cardiology. The results showed that the 16HI-REZ scanner is the best scanner of the six scanners for simulating of cardiac PET images


Subject(s)
Tomography, Emission-Computed , Diagnostic Imaging
SELECTION OF CITATIONS